Ideally, you ought to have an airtight barrier over and below your fiberglass batts. If you can reach All those two air barriers, then wind-washing isn't a concern in a very roof like yours. (It can be in the vented unconditioned attic, naturally, Primarily near the soffits.)

Your assembly requires about 5 inches of XPS, for a complete R-value of only R-twenty five. Which is not A lot. For those who are going to all that trouble to build a sophisticated roof assembly, you need to aim increased.

1. You'll want to get an engineer To judge the safety of one's 2x4 rafters. "Furring down with 2x2s" doesn't Increase the means of one's 2x4s to bear the snow load. It is achievable that an engineer will suggest you to sister 2x8s or 2x10s on to your present 2x4 rafters.

Did you know the original resource for this photo and if it can be done to look at other photos of this intriguing failure.

Many of my neighbors right here have cathedral ceilings, no attics and Unquestionably no insulation (basically they've aluzinc roofs on plywood with pine rafters).

Inevitably, manufacturers began supplying stiffer alternatives that are greater capable of resist the pressures of dense-packed insulation. These products and solutions occur and go, and lots of are now not accessible.

If a building inspector insists that you install some sort of interior “vapor barrier,” you may constantly put in a smart vapor retarder like MemBrain to satisfy your inspector.

Having invested all my life guiding a desk focusing on this is a bit of a split. The roof will be done in Potentially 4 sections so could consider rigid foam and spray foam to match what will work. Rigid foam is monotonous but negligible sticky residue. Thanks.

(d) There might be adequate air leakage for the "soffit" and ridge to offer air movement that functions the way a air flow gap ordinarily would.

an air barrier. If you intend to put in EnGard insulation batts within an unvented cathedral ceiling, you'll need to have a substantial layer of rigid foam insulation earlier mentioned the roof sheathing.

You do not demonstrate whether or not This can be new construction or the renovation of the present building. I somewhat suspect This is a renovation -- or else 1 may well are convinced the designer on the building would even have furnished a style for the roof.

Doug... For a few motive I did't see your put up #17. Appears like two of us at the least Imagine there is likely to be a very easy inexpensive Option.

In case you are creating a cathedral ceiling, the greatest air-barrier blunder is to put in tongue-and-groove boards as your end ceiling without having first putting in taped gypsum drywall. A board ceiling is notoriously leaky, and such a ceiling is frequently related to roof sheathing rot.

Code interpretations are subject for the perseverance of your neighborhood creating inspector. Eventually, it does read more not issue what I think -- what issues is what your neighborhood code official thinks. So question her or him.